销售西门子变频器30KW

更新时间:2017-05-04 14:43:51 信息编号:5134491 发布者IP:180.174.45.228 浏览:34次
供应商
上海地友自动化设备有限公司 商铺
认证
资质核验:
已通过营业执照认证
入驻顺企:
8
主体名称:
上海地友自动化设备有限公司
组织机构代码:
91310117MA1J20GF1A
报价
人民币¥88.00元每台
品牌
西门子
型号
6SE6440-2UD33-0EB1
3
9
关键词
S7-200CN、S7-200、Smart200、连接器,变频器,电源模块,S7-300、S7-400、S7-1200、触摸屏、6FC、6SN、S120、V10、V20、V60、V80、G110、G1
所在地
上海市松江区叶榭镇叶旺路1号1楼
手机号
18701852718
经理
黄世鹏  请说明来自顺企网,优惠更多
让卖家联系我

产品详细介绍

 销售西门子变频器30KW   销售西门子变频器30KW    销售西门子变频器30KW 6SE6440-2UD33-0EB1 MICROMASTER 440,不带滤波器,3AC 380-480V +10/-10% 47-63Hz,恒转矩,额定输出功率,30 KW 过载 150%,用于 60S,200% 3 S,平方转矩,额定输出功率,37 KW 650 x 275 x 245 (H x W x D),防护等级 IP20,环境温度 -10 - +50 ℃,不带 AOP/BOP; 产品图片: 西门子MM440变频器不带滤波器380-480V  30KW 6SE6440-2UD33-0EB1 6SE6440-2UD33-0EB1西门子MM440变频器30KW 6SE64402UD330EB1 6SE6440-2UD33-0EB1 相似图像 MICROMASTER 440,不带滤波器,3AC 380-480V +10/-10% 47-63Hz,恒转矩,额定输出功率,30 KW 过载 150%,用于 60S,200% 3 S,平方转矩,额定输出功率,37 KW 650 x 275 x 245 (H x W x D),防护等级 IP20,环境温度 -10 - +50 ℃,不带 AOP/BOP 列表价(不含增值税) 显示价格   您的单价(不含增值税) 显示价格   PDF 格式的数据表 下载 服务和支持 (手册,认证,问答...) 下载     产品 商品编号(市售编号) 6SE6440-2UD33-0EB1 产品说明 MICROMASTER 440,不带滤波器,3AC 380-480V +10/-10% 47-63Hz,恒转矩,额定输出功率,30 KW 过载 150%,用于 60S,200% 3 S,平方转矩,额定输出功率,37 KW 650 x 275 x 245 (H x W x D),防护等级 IP20,环境温度 -10 - +50 ℃,不带 AOP/BOP 产品家族 订货数据总览 产品生命周期 (PLM) PM300:有效产品 价格数据 价格组 / 总部价格组 IB / 列表价(不含增值税) 显示价格 您的单价(不含增值税) 显示价格 金属系数 无 交付信息 出口管制规定 AL : 3D225 / ECCN : 3D202W 工厂生产时间 22 天 净重 (Kg) 20.0 Kg 产品尺寸 (W x L X H) 未提供 包装尺寸 未提供 包装尺寸单位的测量 未提供 数量单位 1 件 包装数量 未提供 其他产品信息 EAN 未提供 UPC 未提供 商品代码 85044097 LKZ_FDB/ CatalogID DA51-J 产品组 9823 原产国 中国 Compliance with the substance restrictions according to RoHS directive 阐明 RoHS 合规性 产品类别 未提供 电气和电子设备使用后的收回义务类别 没有电气和电子设备使用后回收的义务 分类     版本 分类 eClass 5.1 27-02-31-01 UNSPSC 15 39-12-20-01  |  捆绑销售:  6SE6440-2UD31-1CA1 MICROMASTER 440,不带滤波器,3AC 380-480V +10/-10% 47-63Hz,恒转矩,额定输出功率,11 KW 过载 150%,用于 60S,200% 3 S,平方转矩,额定输出功率,15 KW 245 x 185 x 195 (H x W x D),防护等级 IP20,环境温度 -10 - +50 ℃,不带 AOP/BOP    6SE6440-2UD23-0BA1 MICROMASTER 440,不带滤波器,3AC 380-480V +10/-10% 47-63Hz,恒转矩,额定输出功率,3 KW 过载 150%,用于 60S,200% 3 S,平方转矩,额定输出功率,3 KW 202 x 149 x 172 (H x W x D),防护等级 IP20,环境温度 -10 - +50 ℃,不带 AOP/BOP    6SE6440-2UD25-5CA1 MICROMASTER 440,不带滤波器,3AC 380-480V +10/-10% 47-63Hz,恒转矩,额定输出功率,5.5 KW 过载 150%,用于 60S,200% 3 S,平方转矩,额定输出功率,7.5 KW 245 x 185 x 195 (H x W x D),防护等级 IP20,环境温度 -10 - +50 ℃,不带 AOP/BOP    6SE6440-2UD21-5AA1 MICROMASTER 440,不带滤波器,3AC 380-480V +10/-10% 47-63Hz,恒转矩,额定输出功率,1.5 KW 过载 150%,用于 60S,200% 3 S,平方转矩,额定输出功率,1.5 KW 173 x 73 x 149 (H x W x D),防护等级 IP20,环境温度 -10 - +50 ℃,不带 AOP/BOP    6SE6440-2UD22-2BA1 MICROMASTER 440,不带滤波器,3AC 380-480V +10/-10% 47-63Hz,恒转矩,额定输出功率,2.2 KW 过载 150%,用于 60S,200% 3 S,平方转矩,额定输出功率,2.2 KW 202 x 149 x 172 (H x W x D),防护等级 IP20,环境温度 -10 - +50 ℃,不带 AOP/BOP   Safety Integrated for SINAMICS S120 built-in units 产品信息 跳转到 Overview Functions Overview The integrated safety functions of SINAMICS S120 provide highly effective application-oriented protection for personnel and machinery. They are suitable for machines and systems that require flexible safety functions and support the setup of tailored safety concepts. SINAMICS S120 offers Extended Functions (SS1 with SBR/SAM, SS2, SOS, SLS, SDI, SSM, SLP, SP, SBT) in addition to Basic Functions (STO, SS1, SBC). The SP function and the SBT diagnostic function go beyond the functional scope according to IEC 61800‑5‑2. The Safety Integrated functions are fully integrated in the drive system. They can be activated as follows: Via safety-related inputs on the CU310‑2 Control Unit Via safety-related inputs on the TM54F Terminal Module Via PROFIBUS or PROFINET with the PROFIsafe profile The Safety Integrated functions are implemented electronically and therefore offer short response times compared to solutions with externally implemented monitoring functions. As an alternative to controlling via terminals and/or PROFIsafe, there is also the option to parameterize several safety functions without selection. In this mode, after parameterization and a POWER ON, these functions are permanently selected. Example: "SLS without selection" can be used, for example, to monitor the maximum velocity to prevent the drive from exceeding a mechanical speed limit. For this purpose, using the "without selection" function, an F‑DI does not have to be used; an F‑CPU is also not required. Safe speed/position sensing Incremental encoders or absolute encoders can be used for safe sensing of the position values on a drive. Safe actual value sensing relies on redundant evaluation of the incremental tracks A/B that supply sin/cos signals of 1 Vpp. Only encoders of the type whose A/B track signals are created and processed using purely analog techniques can be used. The encoder signals can be input via the Sensor Modules. HTL/TTL encoders can be used in a 2-encoder system to achieve safe actual value sensing. The minimum possible speed resolution must also be taken into account. The encoder signals are input via the SMC30 Sensor Module. As an alternative, motors with an integrated DRIVE-CLiQ interface can be used. The speed or position actual values are generated directly in the motor as safe values and are transferred to the Control Unit over safe communication via DRIVE-CLiQ. The encoder must be mechanically attached in such a manner that the encoder shaft is unable to unplug or slide off. For notes on this, see IEC 61800‑5‑2: 2016, Table D.16. A list of Siemens motors that fulfill the electrical and mechanical requirements is available at: https://support.industry.siemens.com/cs/document/33512621 The following can be used for safe speed/position sensing: Single-encoder systems or 2-encoder systems Single-encoder systems In a single-encoder system, the motor encoder is used exclusively for safe actual value sensing. 2-encoder systems The safe actual values for a drive are provided by two separate encoders. The actual values are transferred to the Control Unit over DRIVE-CLiQ. When motors without a DRIVE-CLiQ connection are used, a Sensor Module must be provided. Safe actual value sensing without encoder The Extended Functions Safe Stop 1 (SS1) with SAM/SBR, Safely Limited Speed (SLS), Safe Speed Monitor (SSM) and Safe Direction (SDI) are also available for use without encoders (in combination with asynchronous (induction) motors and SIEMOSYN motors). An encoder that is used for the purposes of motor control has no significance for the safety function here. The Safety Integrated Function Manual contains additional information about the encoderless safety functions. https://support.industry.siemens.com/cs/ww/en/ps/19904/man The Extended Functions Safe Stop 2 (SS2), Safe Operating Stop (SOS), Safely Limited Position (SLP), Safe Position (SP) and Safe Brake Test (SBT) always require a safe encoder system. Licensing The Safety Integrated Basic Functions do not require a license. The Safety Integrated Extended Functions do require a license. It is of no consequence here which safety functions are used and how many. The license can be ordered as an option with the memory card. Alternatively, a single-user license can also be purchased. Safe Brake Control The Safe Brake Control is integrated in power units in booksize format. For the Safe Brake Control (SBC) function, a Safe Brake Relay is required for power units in blocksize format, and a Safe Brake Adapter for power units in chassis format. The Safe Brake Relay/Safe Brake Adapter and the brake control that is integrated in the booksize/chassis format allows safe control of electro-mechanical motor brakes. The Safe Brake Relay controls a 24 V DC brake; the Safe Brake Adapter controls a 230 V AC brake. When the STO function is active, the Safe Brake Relay/Safe Brake Adapter safely closes the connected brake. The SBC function monitors the control of the brake, however, not its mechanical functioning. The inverter controls the connected brake using the motor holding brake function. External surge suppressors are not required. The cable harnesses for connection to the Power Module are supplied as standard with the Safe Brake Relay. A connecting cable is required to connect the Safe Brake Adapter. With the Safe Brake Relay/Safe Brake Adapter functions, the brake is controlled in accordance with IEC 61508 SIL 2 and EN ISO 13849‑1 PL d and Category 3. Safe Brake Relay Safe Brake Adapter   Functions Function Control Underlying function Reaction to limit overshoot External setpoint input effective Encoder required1) License required Basic Functions STO EP terminals on the power unit or CUA31/CUA32 and a DI on the Control Unit F-DI on TM54F F-DI on CU310‑2 PROFIsafe SBC (if activated) – No No No SBC With STO (immediately or following expiry of the delay time with SS1) – – – No No SS1 Time-driven EP terminals on the power unit or CUA31/CUA32 and a DI on the Control Unit F-DI on TM54F F-DI on CU310‑2 PROFIsafe STO following expiry of the parameterized delay time, SBC (if activated) STO Can be parameterized No No Extended Functions SS1 with SBR/SAM F-DI on TM54F F-DI on CU310‑2 PROFIsafe Safe Acceleration Monitor (SAM) or Safe Brake Ramp (SBR) during braking. STO and SBC (if activated) following expiry of the parameterized delay time or if the speed falls below the minimum speed limit STO Can be parameterized No Yes SS2 F-DI on TM54F F-DI on CU310‑2 PROFIsafe Safe Acceleration Monitor (SAM) during braking. Following expiry of the parameterized delay time SOS SS1 → STO No Yes Yes SLS encoderless F-DI on TM54F F-DI on CU310‑2 PROFIsafe Continuously activated – STO, SS1 (can be parameterized) Yes No Yes SLS F-DI on TM54F F-DI on CU310‑2 PROFIsafe Continuously activated – STO, SS1, SS2 or SOS (can be parameterized) Yes Yes Yes SOS F-DI on TM54F F-DI on CU310‑2 PROFIsafe – SS1 → STO Yes Yes Yes SSM Always active, if configured – Signals that the speed has fallen below a specified value (safe checkback signal switches to high) Yes No Yes SDI F-DI on TM54F F-DI on CU310‑2 PROFIsafe Continuously activated – STO, SS1, SS2 or SOS (can be parameterized) Yes No Yes SLP F-DI on TM54F F-DI on CU310‑2 PROFIsafe – STO, SS1, SS2 or SOS (can be parameterized) Yes Yes Yes SP Always active, if configured – – Yes Yes Yes SBT Safety Control Channel BICO signals for test stop selection – Signals test result. Warning if test failed Yes Yes Yes 1) Encoderless Safety Extended Functions can be implemented only on request for SINAMICS S120 converters.       全部关于 Safety Integrated for SINAMICS S120 built-in units 产品与解决方案在线目录与订购系统技术信息服务与支持联系人与合作伙伴服务项目      
相关产品:S7-200CN , S7-200 , Smart200 , 连接器 , 变频器 , 电源模块 , S7-300 , S7-400 , S7-1200 , 触摸屏 , 6FC , 6SN , S120 , V10 , V20 , V60 , V80 , G110 , G1
所属分类:中国电子元件网 / 西门子变频器
本页链接:http://product.11467.com/info/5134491.htm
销售西门子变频器30KW的文档下载: PDF DOC TXT
关于上海地友自动化设备有限公司商铺首页 | 更多产品 | 联系方式 | 黄页介绍
主要经营:西门子变频器/西门子触摸屏/西门子电机伺服/
上海地友自动化设备有限公司本着“以人为本、科技先导、顾客满意、持续改进”的工作方针,致力于工业自动化控制领域的产品开发、工程配套和系统集成,拥有丰富的自动化产品的应用和实践经验 ...
我们的其他产品
顺企网 | 公司 | 黄页 | 产品 | 采购 | 资讯 | 免费注册 轻松建站
免责声明:本站信息由企业自行发布,本站完全免费,交易请核实资质,谨防诈骗,如有侵权请联系我们   法律声明  联系顺企网
© 11467.com 顺企网 版权所有
ICP备案: 粤B2-20160116 / 粤ICP备12079258号 / 粤公网安备 44030702000007号 / 互联网药品信息许可证:(粤)—经营性—2023—0112