Optical
Specification (Flattop AWG)
Parameters
|
Condition
|
Specs
|
Units
|
||
Min
|
Typ
|
Max
|
|||
Number
of Channels
|
|
40
|
|
||
Number
Channel Spacing
|
100GHz
|
100
|
GHz
|
||
Cha. Center
Wavelength
|
ITU fre
|
C
-band
|
nm
|
||
Clear Channel
Passband
|
|
±0.1
|
nm
|
||
Wavelength Stability
|
Maximum range of the wavelength
error of all channels and temperatures in average
polarization.
|
±0.05
|
nm
|
||
-1 dB
Channel Bandwidth
|
Clear
channel bandwidth defined by passband shape. For each
channel
|
0.4
|
|
|
nm
|
-3 dB
Channel Bandwidth
|
Clear
channel bandwidth defined by passband shape. For each
channel
|
0.6
|
|
|
nm
|
Optical
Insertion Loss at ITU grid
|
Defined
as the minimum transmission at ITU wavelength for all channels. For
each channel, at all temperatures and polarization.
|
|
4.5
|
6.0
|
dB
|
Adjacent Channel Isolation
|
Insertion loss difference from
the mean transmission at the ITU grid wavelength to the highest
power, all polarization, within the ITU band of the adjacent
channels.
|
25
|
|
|
dB
|
Non-Adjacent, Channel
Isolation
|
Insertion loss difference from
the mean transmission at the ITU grid wavelength to the highest
power, all polarization, within the ITU band of the nonadjacent
channels.
|
30
|
|
|
dB
|
Total
Channel Isolation
|
Total cumulative insertion loss
difference from the mean transmission at the ITU grid wavelength to
the highest power, all polarization, within the ITU band of all
other channels, including adjacent channels.
|
22
|
|
|
dB
|
Insertion Loss Uniformity
|
Maximum range of the insertion
loss variation within ITU across all channels, polarization and
temperatures.
|
|
1.0
|
1.5
|
dB
|
Directivity(Mux Only)
|
Ratio
of reflected power out of any channel(other than channel n)to power
in from the input channel n
|
40
|
|
|
dB
|
Insertion Loss Ripple
|
Any
maxima and any minima of optical loss across ITU band, excluding
boundary points, for each channel at each port
|
|
|
0.5
|
dB
|
Optical
Return loss
|
Input &
output ports
|
40
|
|
|
dB
|
PDL/Polarization Dependent Loss in
Clear
Channel
Band
|
Worst-case value measured in ITU band
|
|
0.3
|
0.5
|
dB
|
Polarization Mode
Dispersion
|
|
|
|
0.5
|
ps
|
Maximum
Optical Power
|
|
|
|
23
|
dBm
|
MUX/DEMUX input/ output
Monitoring range
|
|
-35
|
|
+23
|
dBm
|
IL Represents the worst case over a
+/-0.1nm window around the ITU wavelength
PDL was measured on
average polarization over a +/- 0.1nm window around the ITU
wavelength.
Ordering Part Code
Sequence
AWG
|
X
|
XX
|
X
|
XXX
|
X
|
X
|
X
|
XX
|
|
Band
|
Number of
Channels
|
Spacing
|
1st
Channel
|
Filter
Shape
|
Package
|
Fiber
Length
|
In/Out
Connector
|
C=C-Band
L=L-Band
D=C+L-Band
X=Customize
|
16=16-CH
32=32-CH
40=40-CH
48=48-CH
XX=Special
|
1=100G
2=200G
5=50G
X=Special
|
C60=C60
H59=H59
C59=C59
H58=H58
XXX=special
|
G=Gaussian
B=Broad Gaussiar
F=Flat Top
|
M=Module
R=Rack
X=Special
|
1=0.5m
2=1m
3=1.5m
4=2m
5=2.5m
6=3m
S=Specify
|
0=None
1=FC/APC
2=FC/PC
3=SC/APC
4=SC/PC
5=LC/APC
6=LC/PC
7=ST/UPC
S=Specify
|