assembling
instruction
earth fault and short circuit indicator type ekl4
(panel instrument)
descrition
the earth fault and shot circuit
indicator consists of:
l
1 pc reading
instrument (panel instrument)
l
3 pcs sensors for
detecting short circuit current
l
4 pcs linght
cable
l
1 pc sensor for
observing the sum current
l
1 pc flashing lamp
(optional)
installation of the reading
instrument
the earth fault and short circuit indicator is designed for panel
installation .the necessary dimensions of the cutout are
91.5+0,6x44.5+0,6mm ( refer to figure 2 ) .before sliding in the
instrument , the electrical connections can be accomplished .the
housing is slded into the opening and pushed with a light pressure
up to stop position .springs ( figure l ) serve to keep the reading
instrument in its position .
installation of the light cable
the sensor which is installed on the cable,is connected to
the reading instrument via light cable.therefore the sensor
of core l 1has to be connected with the terminal l1 on the
back of the reading instrument.(the endings of the light
cables have to be pushed into the pick-up openings up to
stop position.)the same has to be done with the sensors l2,
l3 and the earth fault sensor 14(figure 3).
power supply
the power supply is performed via a 3.6 v lithium
battery.for exchanging the battery,a screw cap
on the front side of the indication housing must
be removed by turning it left.the battery must be
taken out and replaced by a new one.(with the
supply via lithium battery,the 230 vac are only
connected in case the erath fault and short circuit
indicator type ek shall be reset also via recovering
voltage of the net.)
electric connection
depending one the version,the electrical connection has to be done
according to the designations in figure 3.
terminals without any marking(nc)are without any function.in
principle,the information indicated on the reading instrument is
valid.
setting the display time
the time of displaying after a short circuit or earth is
adjustable.
there are three times to choose.the standard reste times
are:1-2
-4h(other values are possible).the adjustment of the reset
times
will be done by a rotaryswitch.the rotary switche is on the
front
side of the indicator in the left top corner.the possible
switch
positions are shown if figure 4.
setting the operating points for short circuit
the adjustment of the operating points of the earth fault and shore
circuit indicator indicator type ekl4 is done at the sensors.three
different operating points can be adjusted.the operating points are
adjusted with a rotary switch at the front side of the sensor.the
adjustable operating points are indicated on the front side of the
sensor.